Allen Bradley 1756 Controllogix

CompactLogix™ Controllers User manual, publication 1769-UM007 ControlLogix System User Manual, publication 1756-UM001 DriveLogix™ System 5720 User Manual, publication 20D-UM002 DriveLogix5730 Controller for PowerFlex® 700S Drives with PhaseII Control User Manual, publication 20D-UM003 FlexLogix™ Controllers User Manual, publication 1794. ControlLogix Power Supply Installation Instructions 1756-5.78 1756-PH75 ControlLogix 125V DC (90-143V) Power Supply 1756-IN589 1756-Series ControlLogix Module Installation Instructions (Each module has separate installation document.) Multiple 1756-IN numbers 1756-CNB, -CNBR Using ControlNet Communication Modules in Logix5000 Control Systems User Manual.

Artificial Intelligence + Machine Learning. The corporate performance index user's manual. Industry. Mobile.Networking.Security.Sovereign Clouds.Storage.Web.Windows Virtual Desktop.

Rockwell Automation Publication 1734-UM018B-EN-P - October 2013

69

Configure the Adapter for Direct Connection and Rack Optimization in RSLogix 5000 Software Chapter5

10. Click OK.

At this point, your POINTBus status LED should be solid green. All the
yellow triangles in your I/O configuration should be gone.

11. Click OK to close the dialog.
12. Click File

  • Also for: 1756 controllogix, 1769 compact guardlogix, 1789 softlogix, 1756 guardlogix, 5069 compactlogix, 5069 compactguardlogix. × Bookmark added × Added to my manuals.
  • Encoders and sensors to efficiently use your ControlLogix High Speed Counter module. In this manual, we assume that you know how to use these products. 1756 Series ControlLogix System User Manual 1756-UM001 ControlLogix Digital I/O Modules User Manual 1756-6.5.8 ControlLogix Analog I/O Modules User Manual 1756-6.5.9.
  • ControlLogix System User Manual, publication 1756-UM001 Describes how to install, configure, program, and operate a ControlLogix system. ControlLogix Chassis and Power Supplies Installation Instructions, publication 1756-IN005 Describes how to install and troubleshoot standard and ControlLogix-XT™ versions of the 1756 chassis.

Save to save the project.

Access Module Data

Controllogix System User Manual 1756-um001 Tool

Use the following information to use the I/O adapter data in the ladder logic
program:

POINT_IO_Adapter — the name you gave to your EtherNet adapter

# — slot number of POINT I/O module

C — configuration, I = input, O = output

Use the controller tags in your ladder program to read input data or write output
data.

1756 L83e User Manual

For ControlLogix controller information, refer to ControlLogix System
User Manual, publication

1756-UM001

.

Slot Status Bits: The Slot Status bits display the connection status for each
of the POINT I/O modules that use a rack-optimized connection.

Bit 0 is reserved for the adapter and always reports a value of 1.

Each of the other bits (1 to 63) correspond to a POINT I/O module
that you install in the POINT I/O backplane.

In this example, we configured the 1734-AENT adapter for both rack-
optimized and direct connections.
The slot status bits indicate that we installed the module in slot 2 with it
operating correctly:

0 = module participating with no errors and
1 = module not participating or connection error (typically, module
removed/missing)