Schlage 22 Rim Exit Device User Manual

Schlage 22 Rim Exit Device User Manual 3,9/5 9603 votes

RELATED FAQS

Answer
The sequence card part number is 3426 and plugs in the 'S' slot of a control boxes right next to the 10 pin terminal strip.The 7902/7902ES or 7982/7982ES can be converted to a 7902S/7902SES or 79..

Best prices and service on Detex 21 Series Classroom Lever Trim at locksandsafes.com. View and Download Allegion Schlage L-Series service manual online. Schlage L-Series Door locks pdf manual download. Fire/cylinder dogging rim exit device (12 pages) Door locks Allegion 880DT Service Manual. Von duprin 880, 606, 608, & 609 series trim (10 pages). A limited lifetime warranty is provided to the Original User, subject to the.

Rand solar attic fans provide needed ventilation to decrease moisture and water vapor in your attic. Our attic fans remove large amounts of hot air from your attic. This, combined with the decreased attic temperature, can increase the longevity of your entire roof system! Listed below are even more benefits of Rand Solar Attic Fans. Rand Solar Attic Fans are very simple to install. It makes an easy do-it-yourself project that you can do without any prior experience with this sort of thing. Depending on what type of rand attic fan that you purchased, the attic fan installation process may differ. Rand solar rooftop fan user manual instructions.

The Von Duprin Pneumatic PN98/99 series exit devices feature provides remote latch bolt retraction in hazardous areas where electrically operated devices would not be permitted.
The Von Duprin Pneumatic or 'PN' device was designed for Intrinsically Safe Class 1, Division 1 applications.
4810 series is a Top Jamb Pull Side application.4820 series is a Top Jamb Push Side application.4840 series is a Parallel Arm Push Side application.
The 4840 and the 4810 are they only cylinders that can be interchanged, they use the same cylinder for their individual applications.
If using the LCN pneumatic control box as the air source for the Von Duprin Pneumatic devises then you have to use the LCN 925 tubing because of the size of air line fitting on the LCN co..
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices.
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below. Kits include the solenoid, plunger, spring, and washer.6000 Series solenoid Kit 12VDC -..
Changing the handing on a Von Duprin 373L trim requires following parts on all lever designs EXCEPT #12:RHR requires part number 090092-00 (LEVER CONTROL SPRING RHR PKG/4) and 050597-..
Please see the Maintenance Kit Manual for information on device lubrication as well as complete breakdowns and parts lists for Von Duprin exit devices.Exit devices and latc..
A B663 exploded view can been found here.
Falcon (19. 24, 25, and XX) parts manuals for Exits are downloadable on the
Von Duprin has a maintenance kit part number 050046-00 and maintenance instruction, part number 941079-00 for 98/99 series devices. There are some common parts between 98/99 series and 22..
Followings are the steps to convert the Von Duprin 88TP to 88L device.Need to replace the back plate on the 88 exit device, part number 050103. Order a 373L trim and specify handing.Recomme..
To convert the Von Duprin 6000 series electric strikes from FS to FSE or from FSE to FS follow these steps:Remove the electric strike face plate.Remove the strike box cover pl..
Part numbers:FS slider, part # 970387 (6211WF/6212WF/6221/6223 only)FS slider, part # 970388 (Except 6211WF/6212WF/6221/6223)FSE slider, part # 970388 (6211WF/6212WF/6221/6223 only)FSE sl..
User
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper..
Number of reasons could Von Duprin 55 or 88 series cross bar to sag. Attached are the reasons that could cause the cross bar to sag or not lift.The hinge case spring lifts both lever arms and t..
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2..
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.
The maximum 925 tubing run length from the Control Box to the Door Closer is: 7980 Series Control Boxes --- 50 'Linear' feet from Control Box to Door Closer. 7900/7940 Series Control Boxes --..
The circuit board is sometimes referred to as a 'module' in the field.
The 050535-00 replaces the old Von Duprin EL solenoid part number 971687.
A 3' exit device can not be modified to a 4' exit device. You will need to replace the device with a 4' one.
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4' mortise cylinder with an inverted straight cam is required for CD option on Von Dupr..
Order E-Trim Mech Kit part #050671-00 which will include a new solenoid already mounted to the blocking mechanism.See installation instruction # 921297 here which will show how to remove block..
The rim cylinder with thumbturn, XB11-979 (Figure 1) was designed to be installed on the inside head of the Von Duprin 98/99–2 double cylinder exit devices, see Figure 1. The rim cylinder with..
End cap without end cap bracket is 968601.End cap kit with bracket is 900981End cap bracket is 971795-89
You must have the Von Duprin NL Cylinder plate part number 967484-89 to convert the 370 series controls from classroom function to night latch function. If new installation, use the NL cylinde..
A E996 conversion kit is required to convert the 996L/L-BE trim to E996L/L-BE electric trim.050672-00 is the electric conversion kit for 996L rim or vertical rod exit device.050673-00 is the ..
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX8827 Rod Guide Kit part #50482-XX8827 LR Bottom Latch Kit W/Cover part #050467-XX304L Bottom Strike
113781 is the part number for Von Duprin 15 second CX sign.
Part number for Von Duprin standard 15 sec. release Chexit module shipped after 8-24-2015 with motor driven is 040086-00. Part number for Von Duprin standard 15 sec. release Chexit module shi..
This solenoid is replaceable and the part number is 050671.
The part number for Von Duprin exit alarm ALK board is 101030-00.
The Chexit device has a different base plate and center case than the ALK. The Chexit device would need to be replaced with an ALK device.
The part number for 88 series dogging screw is 090004 (package of two) and 090083(package of ten).
HD-EL conversion kit for 3 feet exit device is 050384-00 and for 4 feet is 050385-00.
All Von Duprin exit devices (22, 33/35A ,55 ,88 ,95 and 98/99) use 5/32' dogging key. There are two part numbers available: 090005 is the package of 2 and 090085 is the package of 10.
Answer
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device. Be sure this screw is installed- Exit hardware and strike must be properly mounted ..
In the AD and CO Series replacement parts guide it shows the same part number 46929295 for the 993R, 993S, and 993M. The pictures show that the 993R and 993S have a flat straight tailpiece and the ..
In the early cylindrical version of the AD-Series 993 locks, a spacer may be required for proper cylinder functionality. Effected cylinder types are PD / LD / RD / JDIf a customer is ..
MEASURE THE WOBBLE: When the lever is pressed toward the door, measure the distance of the lever return from the door, then pull on the lever and take a new measurement of the lever retu..
DETERMINE THE CAUSE: Remove the lever:Inspect the spring cage and spindle assembly:The spindel should be held firmly in place by the spring cage. You should not see any movement..
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels.- These are approximate values/levels which change with measurement meters and measure..
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 4 Battery HolderNew batteries = 6.2 VDCLow battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4..
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 8 Battery HolderNew batteries = 12.4 VDC Low battery threshold is 7.2 VDC Critical battery threshold is 6.9 VDC Coin cell = new/..
CO2004 Battery Holder (ONLY) New batteries = 6.2 VDCLow battery threshold is 4.2 VDCCritical battery threshold is 3.9 VDCCoin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY)New batteries = 6.2 VDCLow battery threshold is 4.2 VDCCritical battery threshold is 3.9 VDCCoin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO200 & CO250 Disable coin cell Nuisance delay and blink,With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t..
13 1/2' Long, 3 5/8' Wide, 1/4' Thick
There is not a coin cell on the CO100.
Use a multi-meter in series with the batteries to measure battery current. Be sure your multi-meter can accurately measure very low current, in the micro-amp range.See the attached Technical Not..
Opposite rotation of the lever is intentionally restricted by an internal block device in the spring cage this is normal operation.
Von Duprin 98/99 and 98/99XP Rim/SVR/CVR(steel door only)/Mortise exit devices are compatible with AD200, AD250, AD300, AD400, AD401-993 exit trims.
Von Duprin 22/22F Rim/SVR exit devices are compatible with AD200 and AD250-993 exit trims.
Falcon 25 Rim exit device is compatible with AD200 and AD250-993 exit trims.
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.
Causes for AA battery drain in CO-Series LOCKS - Possible Cause Fix/Corrective Actions One of the four AA batteries was inserted reversed and the reserved battery drains the other batteries. ..
CO-100 now allows the PIN code length to be changed manually. Each CO100 has a label that indicates its firmware revision. Firmware revision 2.5.0 or higher support these..
CO-100 PIN length can range from 3 digits to 6 digits with firmware version 2.5.0 and higher.
Procedure to change PIN length:1. Press {programming code (default is 97531)} then {*}.2. Press {99} then {*}, to enter Special Function Length Menu.3. Press {4} then {*}, to enter Pin Length M..
CO-100 now has NEW lock status reporting capabilities. Battery status, firmware version, hardware version and PCB serial number. See instructions below for these status menus.
The part number for the AD or CO twisted tailpiece kit is: 46929303 Tailpiece Kit - (for Exterior Escutcheon -993 into Exit Device, i.e. Von Duprin 98 or 99) Exit Trim 46929303 Includes the..
ALL AD and CO products are warranted for electrical for 1.0 year after installation OR 2.0 years after manufacture. The mfg date is on the lock stickers AND can be viewed electronically with th..
No, the CO100 is not tested with the Precision 2800, only the 21
The Schlage AD/CO trims are not compatible with the Falcon 25-V device due to the main cam on the device rotating the opposite direction for a given hand compared to the AD/CO trims output dri..
Technically no, the latch cannot be held back.But a CO lock with 50 function can lock be set to remain unlocked (lever active); this would not qualify as dogging.
The CO locks are fire rated for 3 hours.
All finished surfaces of the AD and CO lock is has the microbial finish
In the event of battery failure, the lock will fail As-Is. ( Lock remains in current state, locked or unlocked, until batteries are replaced.)
CO-Series locks, AD-Series locks, AD-Series Reader Modules, WPR400, WRI400, WSM400, TK400, CT5000, PIM400, PIM401, PIB300, and PIB301 are warranted for a period of 12 months from the date of instal..
Job Specific Warranty - If job specific warranty letters or certificates are required, please refer to the Allegion Contact Us web page and request the applicable information.NOTES:F..
AD/CO use the same template as the the 993R
The functionality of AD300 and AD400 devices is dictated by the the supported lock types of the Access Control Panel (ACP). As such, the function cannot be changed at the lock using the HHD.
The CO series locks use a standard instruction manual for all locks. The rehand drawings do not match CO100. The photos show the reader module being removed so the front plate can be removed. This ..
This information can be found at the following URL's:AD200/AD250/AD300/AD400 Cylindrical http://w3.securitytechnologies.com/irstdocs/installinstructions/102104 P516-092.pdf
AD200/AD250/AD300/AD400 Mortise http://w3.securitytechnologies.com/irstdocs/installinstructions/102106 P516-093.pdf
AD200/AD250/AD300/AD400 Cylindrical Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102264 P516-094.pdf
AD200/AD250/AD300/AD400 Mortise Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102263 P516-095.pdf
CO100/CO200/CO250 Cylindrical http://w3.securitytechnologies.com/irstdocs/installinstructions/104214 P516-266.pdf
CO100/CO200/CO250 Mortise http://w3.securitytechnologies.com/irstdocs/installinstructions/104213 P516-267.pdf
CO-Series Cylindrical Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102297 P516-268.pdf
CO-Series Mortise Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102296 P516-269.pdf
This information can be found at the following URL's:AD200 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_AD-200_Offline_Lock_User_Guide_-_English_102107.pdf
AD250 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_AD-250_Offline_Lock_User_Guide_-_English_102108.pdf
AD300 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_Utility_Software_User_Guide_6.4.2_104390.pdf
AD400 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_AD-400_and_AD-401_Networked_Wireless_Lock_User_Guide_104387.pdf
CO100 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_CO-100_Offline_Lock_User_Guide_-_English_104210.pdfCO200 http://us.allegion.com/content/dam/allegion-us-..
CO250 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_CO-250_User_Guide_English_104208.pdf
The original 4B battery holder used with the AD and CO Series products is updated to improve performance. The issues addressed include:- Improved spring ..

Sargent Rim Exit Device

The original 4B battery holder used with the AD and CO Series products is updated to improve performance. The issues addressed include:- New ledges are added near eac..
AD and CO series -993-R model locks will work with most Von Duprin 98/99 series model push bars exit devices – Rim, CVC - Concealed Vertical Cable or CVR - Concealed Vertical Rod AD Series -200/250..
these locks with work with JD-CO6 and JD-CO7

Schlage 22 Rim Exit Device User Manual Blue Light

- Von Duprin 98/99 and 98/99XP Rim/SVR/CVR(steel door only)/Mortise exit devices are compatible with AD200, AD250, AD300, AD400, AD401-993 exit trims.

Schlage 22 Rim Exit Device User Manual Download

- Von Duprin 22/22F Rim/SVR exit devices are compatible with AD200 and AD250-993 exit trims.
- Falcon 25 Rim exit device is compatible with AD200 and AD250-993 exit trims.
- Yale 7110-SVR is NOT compatible with AD-Series products
- AD-series and CO-series exits use a rotational input to unlock the door, exit devices that require a lifting motion istead of rotational, are NOT compatible with AD-series exit devices.
Do CO locks come with a Door Position Switch (DPS) switch?No, all CO locks do not come with the DPS switch unless the lock is ordered as privacy function 40, since the CO can't be changed or re-cla..
Download Link for: CO-100 Offline Lock User Guide - EnglishDownload Link for: CO-Series Cylindrical Installation InstructionsDownload Link for: CO-Series Mortise Insta..

Rim Exit Device Definition

The customer would need to order the spacer that fits between the door and the the lock base plate, to space the lock over the surface vertical rod. Otherwise the 993-R is the same lock as th..

What Is Rim Exit Device

An AD or CO lock with keypad will go into lockout mode and stops responding to key presses after 20 wrong key presses and then the lock remains in timeout and unresponsive for 30 seconds.Wait 30 se..
To remove an AD or CO series lever requires a push pin type Pin Wrench (included with all new locks) or Lever Removal Tool used to depress the knob stop pin.The knob stop pin is located through a ..

Von Duprin Rim Exit Device

What are the AD / CO Steel Lever Set Screw details?AD/CO Steel Lever Set Screw, Tapered Point AD/CO 993: 1/4-28 x 1/2' &..
Where can I find a parts listing for CO series Locks? (Includes CO-100, CO-200, CO-220, CO-250)Download link for: CO Series Service Manual