Each of our US Balance scales is fully digital, providing incredible accuracy and precision that you would expect from larger machines. Enjoy various features including measuring in a variety of units, from grams to ounces to carats to grains and more, with precision down to 0.1g. US Balance Scales. The scale can be read when the lock sign “ ” is shown in the display. TARE FUNCTION Turn on the scale as described above, place the “tare item” on the platform, press the “ZERO” button to zero out the display, when “0.00” appears on the screen you may now place items on the scale.
US-MAGNUM Use & Care Instructions
Thank you for purchasing a US Balance pocket scale. We are confident that with normal
use and proper treatment your scale will provide you with years of reliable service. Please
read all the operation instructions carefully before you use your new scale.
Display Messages:
View & download of more than 7 Us balance PDF user manuals, service manuals, operating guides. Scales user manuals, operating guides & specifications. US Balance has many models of miniature digital pocket scales to choose from. We are a wholesale supplier of pocket scales. All of our pocket scales are manufactured to the highest specifications and covered by our industry-leading warranty. Dec 02, 2013 This item Magnum 500 by US Balance 500 x 0.1 gram Digital Pocket Scale American Weigh Scales Signature Series Digital Precision Pocket Weight Scale, Black 1000G x 0.1G (2019 NEW) Brifit Digital Mini Scale, 200g /0.01g Pocket Scale, 50g calibration weight, Electronic Smart Scale, 6 Units, LCD Backlit Display, Tare, Auto Off, Stainless Steel. Headquartered in Parsippany, NJ, OHAUS Corporation manufactures an extensive line of weighing scales, lab equipment and lab instruments that meet the weighing, sample processing and measurement needs of multiple industries. We are a global leader in the laboratory, industrial and education markets, as well as a host of specialty markets, including the food preparation, pharmacy and jewelry. US Balance US-MAGNUM-1000XR - 1000g x 0.1g User Manual. Using the MODE key, you can switch between weighing units. Place the “tare item” (Ex: container) on the platform. Press the TARE button; wait until '0.0' will be displayed. Press the “MODE” button to change weighing modes on your scale.
• LO – Low battery; please change the batteries in the scale.
• OuEr- The load cell of the scale is being overloaded. You need to remove the
excessive weight from the scale immediately.
• UnSt – The scale is placed on an unstable surface, please move the scale to a
more stable surface.
• rCAL – the scale can not return to zero, please recalibrate the scale.
• CAL – To calibrate the scale, please see details below.
• PASS – you have successfully calibrated your scale, you are now able to use the
scale.
• FAIL – Calibration has failed, please make sure you have the scale on a stable
surface and that you are using the correct weight to calibrate the scale. Try to
calibrate the scale following the calibration instructions exactly.
US Balance Scale Instructions:
ON/OFF FUNCTION
Place your scale on a flat and stable surface away from any electronic equipment that
may interfere with the scale. Press and release the ON/OFF button, wait until the display
shows “0.0” and the zero-stable sign “ ”, you may now place the object you want to
weigh on the platform. The scale can be read when the lock sign “ ” is shown in the
display.
TARE FUNCTION
Turn on the scale as described above, place the “tare item” on the platform, press the
“TARE” button to zero out the display, when “0.0” appears on the screen you may now
place items on the scale to be weighed. Once you are finished weighing, remove all
objects from the scale, press the “TARE” again to cancel the TARE FUNCTION.
RETURN TO ZERO
After weighing an item, if the display does not read “0.0” press the ZERO/TARE button
to return to “0.0” and you are ready to weigh again.
US-MAGNUM-1000XR– User Manual
Capacity: 1000g x 0.1g - Weighing modes: g, oz, ozt, dwt, gn, ct
Thank you for purchasing US-MAGNUM-1000XR digital scale. Please read
all operation instructions carefully before use.
Scales are precision instruments and should always be handled with proper
care. To ensure years of reliable service, keep these simple tips in mind:
Do not exceed the scales maximum capacity. Overloading your scale can
permanently damage it!
Avoid exposure to extreme heat or cold. Scales perform best at normal room
temperature. If temperatures have changed dramatically, recalibration may
be necessary.
Allow your scale to warm up for 30-60 seconds before performing calibration
(if available).
Store your scale in a clean, dry location. Dust, dirt, and moisture can
accumulate on the weighing sensors and electronics causing inaccuracy or
malfunction.
Avoid using you scale in close proximity to strong radio wave emitting
devices such as computers, cash registers, and cordless phones.
Digital Scale Food
Always weigh on a flat level surface, free from vibrations and drafts. The
corner of a room is usually the most stable.
Gently apply all items to be weighed. Do not drop items onto the weighing
platform.
Avoid dropping your scale. The warranty does not cover damage due to
rough treatment or overload.
I
- SCALE OPERATION
Place the scale on a horizontal flat surface
1. Press ON/OFF key.
2. Wait until the display shows “0.0” and the zero-stable sign
3. Place the object(s) on the weighing platform.
4. Using the MODE key, you can switch between weighing units.
2-TARE WEIGHING
The Tare function will allow you to remove a known weight of an object,
usually the weighing container, to zero a scale.
1. Turn on the scale as described above
2. Place the “tare item” (Ex: container) on the platform.
3. Press the TARE button; wait until '0.0' will be displayed.
4. Place items on the scale to be weighed
Us Balance Us-boss Digital Scale User Manual Pdf
Once you are finished weighing, remove all objects from the scale, press the “TARE”
again to cancel the TARE FUNCTION
3-RETURN TO ZERO
After weighing an item, if the display does not read “0.0” press the ZERO/TARE
button to return to “0.0” and you are ready to weigh again.
4- CHANGE WEIGHING MODES
Press the “MODE” button to change weighing modes on your scale. This scale has 6
weighing modes: g, oz, gn, ct, ozt, dwt.
5-CALIBRATION
This scale has come pre-calibrated at the factory. Only re-calibrate if you are
experiencing trouble weighing.
1. Press ON/OFF key, to turn on to the scale, until [0.0] is displayed.
2. Press and hold the CAL key, until the display read [CAL] and then [500.0] will
flash in the LCD.
3. Place a 500g Cal-weight on the center of the platform.
4. The LCD display reads [PASS] and then [500.0].
5. Calibration succeeds, and the scale is ready for normal use now
6. Remove the weight and press ON/OFF to turn off the scale. Finish!
6-PARTS COUNTING FUNCTION
1. Place a quantity of 10 pcs of the item you want to count on the platform (Ex:
10 coins).
2. After the display shows the weight of the items, press the 'PCS' button until
you see number 10 on the screen.
3. Press the 'PCS' button again; 'PCS' function has been set. (“PCS' will be on
For those who aren't confident about installing an air conditioner themselves, you can ask the retailer when you're purchasing a new one, or try a service like HomeAdvisor. How much does an air conditioner cost? The cost of an air conditioner varies by type and functionality—you can spend anywhere from $100 to several thousand dollars. Apr 12, 2014 Tutorial on how to properly install your LG Portable Air conditioners. This video is intended for assistance with installation on the following models: LP0711WNR - 7,000 BTU. Lg air conditioner user manual. All Products, The Honeywell Store allows you to buy quality products at a great price from the convenience of your own home. This includes Honeywell Fans, Heaters, Safes, Generators, LED Light Bulbs, Thermostats, Air Purifiers, Commercial Air Cleaners, Vacuum Replacement Bags, Replacement Filters, Muck Boots and More. Jul 10, 2014 Learning how to install a portable air conditioner requires just a few easy steps. #TheHomeDepot #HomeImprovement #DIY SUBSCRIBE to The Home Depot: http://th. Mar 23, 2012 To install a portable air conditioner, start by positioning the unit near both a window and an electrical outlet. Next, connect the exhaust hose to the unit and run it to the window. Then, adjust the window kit sliders or panels until there aren’t any gaps and close the window so that it fits snugly and holds everything in place.
the bottom left corner of the screen).
4. Remove the items and the display will show '0'
You may now count your items as long as their total weight does not exceed 1000g
Once you are finished with the PARTS COUNTING FUNCTION, press the “MODE” again
to cancel the “PCS” function
6-OPERATING ENVIRONMENT
The optimum operating temperature for the scale is 50-86° F/10-30°C. Rough
handling of the scale will damage the internal sensor; so you must avoid actions such
as shaking or dropping the scale. This is a sensitive piece of electronic equipment and
will be affected by things such as moisture, extreme temperature changes, magnetic
fields, careless handling and misuse.
V-AUTOMATIC SHUT-OFF
The scale will automatically shut-off after 60 seconds of inactivity this is to help
conserve the battery power. We recommend good quality AAA batteries.
Tested to comply with FCC standards