Data Sheet (PDF) CAD Data; Manuals; CV-X422F Controller: 2M pixel camera supporting type. Data Sheet (PDF) CAD Data; Manuals; CV-X452A Controller: 5M pixel camera supporting type. Data Sheet (PDF) CAD Data; Manuals; CV-X452F Controller: 5M pixel camera supporting type. Data Sheet (PDF) CAD Data; Manuals; CV-X472A Controller: 21M pixel camera. Data Sheet (PDF) CAD Data; Manuals; OP-M1839 CV-X100 Series Setup Manual. Data Sheet (PDF) CAD Data; Manuals; OP-M1840 CV-X100 Series Setup Manual (English) Data Sheet (PDF) CAD Data; Manuals; OP-M1841 CV-X100 Series Setup Manual (Simplified Chinese) Data Sheet (PDF) CAD Data; Manuals; OP-M1842 CV-X100 Series Setup Manual (Traditional Chinese. OP-M1866, CV-X100 Series User's Manual (English(USA)) in CV-X series by KEYENCE America. Tcm:26-278579-64 To use all available functions on this website, JavaScript must be enabled in your browser. Data Sheet (PDF) CAD Data; Manuals; OP-M1842 CV-X100 Series Setup Manual (Traditional Chinese) Data Sheet (PDF) CAD Data; Manuals; OP-M1844 CV-X Series User's Manual. Data Sheet (PDF) CAD Data; Manuals; OP-M1845 CV-X100 Series User's Manual (English) Data Sheet (PDF) CAD Data; Manuals; OP-M1846 CV-X100 Series User's Manual (Simplified Chinese. View & download of more than 310 Keyence PDF user manuals, service manuals, operating guides. Accessories user manuals, operating guides & specifications. Data Sheet (PDF) CAD Data; Manuals; CV-X422F Controller: 2M pixel camera supporting type. Data Sheet (PDF) CAD Data; Manuals; CV-X452A Controller: 5M pixel camera supporting type. Data Sheet (PDF) CAD Data; Manuals; CV-X452F Controller: 5M pixel camera supporting type. Data Sheet (PDF) CAD Data; Manuals; CV-X472A Controller: 21M pixel camera. CV-X302F, 0.47 megapixel camera supporting type Controller in CV-X series by KEYENCE America. T0317603 To use all available functions on this website, JavaScript must be enabled in your browser.

CV-X EASY CONFIGURATION MANUALS

Control via I/O portEasy Setup Guide Control/Communication I/O
(for CV-X100 Series, CV-X200 Series)
English
Easy Setup Guide Control/Communication I/O
(for CV-X400 Series)
English
Control via PLC linkEasy Setup Guide Control/Communication PLC-Link
(KEYENCE KV Series)
English
Easy Setup Guide Control/Communication PLC-Link
(MELSEC Q Series)
English
Easy Setup Guide Control/Communication PLC-Link
(MELSEC FX Series)
English
Easy Setup Guide Control/Communication PLC-Link
(SYSMAC CJ Series)
English
Easy Setup Guide Control/Communication PLC-Link
(YASKAWA MP Series)
English
Control via PROFINETEasy Setup Guide Control/Communication PROFINET
(SIMATIC S7 Series)
English
Control via EtherNet/IPEasy Setup Guide Control/Communication EtherNet/IP
(KEYENCE KV Series)
English
Easy Setup Guide Control/Communication EtherNet/IP
(SYSMAC CJ Series)
English
Easy Setup Guide Control/Communication EtherNet/IP
(Control Logix Series)
English
Control via Non-procedural communicationEasy Setup Guide RS-232C Non-procedural communicationEnglish
Data storage via FTPEasy Setup Guide FTP Image Output - FileZillaEnglish
Advertising

7

*1 The letter at the end of the model number means the difference of the installed software function. For details, see the

'

CV-X Series User's Manual

'

.

*2 The PNP open collector is used for model types with P at the end.
*3 Models that have an Ethernet port installed on the CPU unit support Ethernet port direct connections.
*4 The CA-DC21E supports switching between PWM and DC methods. The CA-DC30E is Constant current control method and the CA-DC10E is fixed to the PWM method.

Main Specifications

Model name

*1*2

CV-X170

CV-X150

CV-X100

Number of pixels

With CA-HX500C/HX500M connected
• 5,000,000-pixel mode:

2432 (H) x 2040 (V), approx. 4,960,000 pixels

• 2,000,000-pixel mode:

1600 (H) x 1200 (V), approx. 1,920,000 pixels

With CA-HX200C/HX200M connected
• 2,000,000-pixel mode:

1600 (H) x 1200 (V), approx. 1,920,000 pixels

With CA-HX048C/HX048M connected
• 470,000-pixel mode:

784 (H) x 596 (V), approx. 470,000 pixels

• 310,000-pixel mode:

Keyence Cv X100 User Manual Pdf 2 8

640 (H) x 480 (V), approx. 310,000 pixels

• 240,000-pixel mode:

512 (H) x 480 (V), approx. 240,000 pixels

With CV-H500C/H500M connected
• 5,000,000-pixel mode:

2432 (H) x 2050 (V), approx. 4,990,000 pixels

With CV-200C/S200C/H200C/200M/S200M/
H200M connected
• 2,000,000-pixel mode:

1600 (H) x 1200 (V), 1,920,000 pixels

• 1,000,000-pixel mode:

1024 (H) x 960 (V), approx. 980,000 pixels

With CV-H100C/H100M connected
• 1,000,000-pixel mode:

1000 (H) x 1000 (V), 1,000,000 pixels

With CV-035C/S035C/035M/S035M/H035C/
H035M connected
• 310,000-pixel mode:

640 (H) x 480 (V), approx. 310,000 pixels

• 240,000-pixel mode:

512 (H) x 480 (V), approx. 240,000 pixels

With CA-HX200C/HX200M connected
• 2,000,000-pixel mode:

1600 (H) x 1200 (V), approx. 1,920,000 pixels

With CA-HX048C/HX048M connected
• 470,000-pixel mode:

784 (H) x 596 (V), approx. 470,000 pixels

• 310,000-pixel mode:

640 (H) x 480 (V), approx. 310,000 pixels

• 240,000-pixel mode:

512 (H) x 480 (V), approx. 240,000 pixels

With CV-200C/S200C/H200C/200M/S200M/
H200M connected
• 2,000,000-pixel mode:

1600 (H) x 1200 (V), 1,920,000 pixels

• 1,000,000-pixel mode:

1024 (H) x 960 (V), approx. 980,000 pixels

With CV-H100C/H100M connected
• 1,000,000-pixel mode:

1000 (H) x 1000 (V), 1,000,000 pixels

With CV-035C/S035C/035M/S035M/H035C/
H035M connected
• 310,000-pixel mode:

640 (H) x 480 (V), approx. 310,000 pixels

• 240,000-pixel mode:

512 (H) x 480 (V), approx. 240,000 pixels

With CA-HX048C/HX048M connected
• 470,000-pixel mode:

784 (H) x 596 (V), approx. 470,000 pixels

• 310,000-pixel mode:

640 (H) x 480 (V), approx. 310,000 pixels

• 240,000-pixel mode:

512 (H) x 480 (V), approx. 240,000 pixels

With CV-035C/S035C/035M/S035M/H035C/
H035M connected
• 310,000-pixel mode:

640 (H) x 480 (V), approx. 310,000 pixels

• 240,000-pixel mode:

512 (H) x 480 (V), approx. 240,000 pixels

Camera input

2 Colour/monochrome cameras, four cameras
with the expansion unit CV-E500 (Supports CA-
HX500C/HX500M/HX200C/HX200M/HX048C/
HX048M and CV-H500C/200C/S200C/H200C/
H100C/035C/S035C/H035C/H500M/200M/
S200M/H200M/H100M/035M/S035M/H035M,
mixed connection possible)

2 Colour/monochrome cameras, four cameras
with the expansion unit CV-E500 (Supports CA-
HX200C/HX200M/HX048C/HX048M and
CV-200C/S200C/H200C/H100C/035C/S035C/
H035C/200M/S200M/H200M/H100M/035M/
S035M/H035M, mixed connection possible)

2 Colour/monochrome cameras (Supports CA-
HX048C/HX048M and CV-035C/S035C/H035C/
035M/S035M/H035M, mixed connection
possible)

Main processor for image processing

DSP (High-Speed)

DSP (Medium)

DSP (Standard)

Number of setting registrations

Up to 1000 settings (depending on SD card capacity and setting contents) for SD card 1 and SD card 2 individually and external switching is possible

Number of reference images

Each setting supports 900 images per camera (depending on SD card capacity), compress and save functions and image registration of position
adjusted images.

Memory card

• SD card slot x2 (SDHC compatible)
• Supports OP-87133 (512 MB: standard equipment on the SD1 slot for the CV-X150/X100), CA-SD1G (1 GB: standard equipment on the SD1 slot for

the CV-X170), CA-SD4G (4 GB)

Interface

Control input

External trigger
input

4 points (2 of which support special function assignment)
Input rating: 26.4 V max., 3 mA min, simultaneous/individual capture with up to 4 cameras (two camera with the CV-X100) is possible
Can set individual trigger delays (0 to 999 ms) for each trigger input

Control input

16 points (4 of which support special function assignment) Input rating: 26.4 V max., 2 mA min.

Control output

Keyence Cv X100 User Manual Pdf

Common output

27 points (11 of which support special function assignment, includes 4 high speed outputs), NPN open collector, 50 mA max. (30 V max.)

Total status output

1 point, NPN open collector, 50 mA max. (30 V max.) Supports total status hold control, one-shot output (1 to 9999 ms)

Monitor output

Cv X100 User Manual

Analogue RGB output
XGA 1024 x 768 (24 bit colour, 60Hz)

Operation indicator

Power and ERROR LED display

RS-232C

Can perform numerical value output and control I/O, supports a max. baud rate of up to 115200 bps
(Cannot be used with PLC-Links using the RS-232C port)

PLC-Link

• Can output numerical values and perform control input/output using the Ethernet or RS-232C port

(Cannot be used in conjunction with EtherNet/IP and PROFINET. When using the RS-232C port, nonprocedural RS-232C communication cannot be
used in conjunction.)

• The following PLCs are supported via link unit:

*3

KEYENCE: KV-700 Series, KV-1000 Series, KV-3000 Series, KV-5000 Series, KV-5500 Series, KV Nano Series
Mitsubishi Electric: MELSEC A Series (RS-232C only), Q Series, L Series, FX Series (RS-232C only)
OMRON: SYSMAC C Series (RS-232C only), CJ/CS1/CP1 Series
YASKAWA Electric Corporation: MP900 Series (RS-232C only)/MP2000 Series

Ethernet

• Can output numerical values and perform control input/output
• Can output measured value and image data via the included PC programme, upload and download settings
• Supports FTP client and FTP server function
• VNC server (for non-PC clients, only displaying the monitor screen is supported)
• Supports BOOTP function
• 1000BASE-T/100BASE-TX/10BASE-T

EtherNet/IP

• Numerical value and control input/output using the Ethernet port enabled (Cannot be used in conjunction with PLC-link / PROFINET).
• Cyclic (implicit) communication (max. 1436 bytes) possible. Message communication possible.
• Maximum connections: 32.
• In conformity with conformance test Version.A9.

PROFINET

• Numerical value and control input/output using the Ethernet port enabled (Cannot be used in conjunction with PLC-link / EtherNet/IP).
• Cyclic communication (max. 1408 bytes) possible. Record data communication possible.
• In conformity with Conformance Class A

Mouse

Baikal izh 35. For more information, go toMANUALSMany of EAA’s online manuals are in Adobe’s pdf format.

Possible to control various menus via an optional dedicated mouse (OP-87506: included with the controller)

Keyence cv x manual

Illumination control

By connecting the optional Illumination Expansion Unit CA-DC30E/21E/10E, lighting and intensity control for the LED illumination is possible.

*4

CA-DC30E: 2ch/unit, up to 2 units can be connected, only supports dedicated illumination unit.
CA-DC21E: 2ch/unit, up to 4 units can be connected, Output voltage 12V/24V.
CA-DC10E: 2ch/unit, up to 1 unit can be connected, Output voltage 12V only, mixed connection with CA-DC30E/21E is not possible.

Language

Switched among English, Japanese, Simplified Chinese, Traditional Chinese, Korean, Thai, German, French, Italian, Mexican Spanish, Indonesian,
Vietnamese and Portuguese (Brazilian)

Rating

Power supply voltage

24 V DC ± 10%

Current consumption

3.0A (When 2 cameras are connected)
3.9A (When 4 cameras are connected)
Figures indicate maximum load including rush current at start-up.

2.6A (When 2 cameras are connected)
Figures indicate maximum load including rush
current at start-up.

Environmental
resistance

Ambient temperature

• When 2 cameras are connected: 0 to +50

°

C (when a 1 megapixel or higher camera is connected:

0 to +45

°

C)

• When 4 cameras are connected: 0 to +45

°

C

0 to +50

°

C

Relative humidity

35 to 85% RH (no condensation)

Weight

Approx. 1250g